VP Heat Insulation Pumice
ACR bl10 G HOLLOW BLOCK SINGLE ROW 10X39X18.5 | ||
CLASS CATEGORY | - | Category 1 |
most | mm | 100 |
size | mm | 390 |
HEIGHT | mm | 185 |
CLASS SIZE TOLERANCE | - | D1 |
Compressive Strength (Characteristic) | N/mm2 | 2.00 |
GROSS RATE mass per unit volume (Avg.) | kg/m3 | 700.00 |
NET RATE mass per unit volume (Avg.) | kg/m3 | 850.00 |
THERMAL RESPONSE CAPABILITY (Max) | W/mK | 0.190 |
SOUND INSULATION VALUE | dB | 38 |
FIRE RESISTANCE | - | A1 |
WATER VAPOR TRANSMISSION | kg/m2spa | 9.00 |
m2 Consumption | 1 m2 | 13 Pcs. |
semi-finished products | there is | --- |
HOLLOW BLOCK TWO LINE ACR bl10 G 10X39X18.5 | ||
CLASS CATEGORY | - | Category 1 |
most | mm | 100 |
size | mm | 390 |
HEIGHT | mm | 185 |
CLASS SIZE TOLERANCE | - | D1 |
Compressive Strength (Characteristic) | N/mm2 | 2.00 |
GROSS RATE mass per unit volume (Avg.) | kg/m3 | 700.00 |
NET RATE mass per unit volume (Avg.) | kg/m3 | 850.00 |
THERMAL RESPONSE CAPABILITY (Max) | W/mK | 0.190 |
SOUND INSULATION VALUE | dB | 38 |
FIRE RESISTANCE | - | A1 |
WATER VAPOR TRANSMISSION | kg/m2spa | 9.00 |
m2 Consumption | 1 m2 | 13Ad. |
semi-finished products | there is | --- |
HOLLOW BLOCK TWO LINE ACER BL 15 G 15X39X18.5 | ||
CLASS CATEGORY | - | Category 1 |
most | mm | 150 |
size | mm | 390 |
HEIGHT | mm | 185 |
CLASS SIZE TOLERANCE | - | D1 |
Compressive Strength (Characteristic) | N/mm2 | 1,80 |
GROSS RATE mass per unit volume (Avg.) | kg/m3 | 715.00 |
NET RATE mass per unit volume (Avg.) | kg/m3 | 900.00 |
THERMAL RESPONSE CAPABILITY (Max) | W/mK | 0.210 |
SOUND INSULATION VALUE | dB | 42 |
FIRE RESISTANCE | - | A1 |
WATER VAPOR TRANSMISSION | kg/m2spa | 9.00 |
m2 Consumption | 1 m2 | 13Ad. |
semi-finished products | there is | --- |
HOLLOW BLOCK THREE ROWS ACR 19X39X18.5 bl10 | ||
CLASS CATEGORY | - | Category 1 |
most | mm | 190 |
size | mm | 390 |
HEIGHT | mm | 185 |
CLASS SIZE TOLERANCE | - | D1 |
Compressive Strength (Characteristic) | N/mm2 | 1,80 |
GROSS RATE mass per unit volume (Avg.) | kg/m3 | 650.00 |
NET RATE mass per unit volume (Avg.) | kg/m3 | 840.00 |
THERMAL RESPONSE CAPABILITY (Max) | W/mK | 0.200 |
SOUND INSULATION VALUE | dB | 46 |
FIRE RESISTANCE | - | A1 |
WATER VAPOR TRANSMISSION | kg/m2spa | 9.00 |
m2 Consumption | 1 m2 | 13Ad. |
semi-finished products | there is | --- |
HOLLOW BLOCK THREE ROW S ACR 25X39X18.5 bl10 | ||
CLASS CATEGORY | - | Category 1 |
most | mm | 250 |
size | mm | 390 |
HEIGHT | mm | 185 |
CLASS SIZE TOLERANCE | - | D1 |
Compressive Strength (Characteristic) | N/mm2 | 1,90 |
GROSS RATE mass per unit volume (Avg.) | kg/m3 | 610.00 |
NET RATE mass per unit volume (Avg.) | kg/m3 | 850.00 |
THERMAL RESPONSE CAPABILITY (Max) | W/mK | 0.230 |
SOUND INSULATION VALUE | dB | 50 |
FIRE RESISTANCE | - | A1 |
WATER VAPOR TRANSMISSION | kg/m2spa | 10.00 |
m2 Consumption | 1 m2 | 13Ad. |
semi-finished products | there is | --- |
ACR BL10 G DÖRTSIRA BOŞLUKLU BLOK 30X39X18.5 | ||
CLASS CATEGORY | - | Category 1 |
most | mm | 300 |
size | mm | 390 |
HEIGHT | mm | 185 |
CLASS SIZE TOLERANCE | - | D1 |
Compressive Strength (Characteristic) | N/mm2 | 1,60 |
GROSS RATE mass per unit volume (Avg.) | kg/m3 | 570.00 |
NET RATE mass per unit volume (Avg.) | kg/m3 | 820.00 |
THERMAL RESPONSE CAPABILITY (Max) | W/mK | 0.200 |
SOUND INSULATION VALUE | dB | 54 |
FIRE RESISTANCE | - | A1 |
WATER VAPOR TRANSMISSION | kg/m2spa | 13.00 |
m2 Consumption | 1 m2 | 10,5Ad. |
semi-finished products | there is | --- |